Check Out Our HVAC Work in Palm Harbor FL
Mason Air Conditioning & Heating is a family-owned HVAC repair and installation company serving the residents of Palm Harbor, FL, and the surrounding areas. We have built our business on 5-star reviews and referrals because we treat our clients the way we’d like to be treated. Whether you need your furnace, boiler, heat pump or central air conditioning attended to, we are the company for you. On top of residential HVAC, we are indoor air quality experts, too! We are also proud to be the Home of the Free Service Call meaning that you don’t owe us a dime until we start actually working on your project.
Mason will give you premium service at an exceptional value, and we’ll never talk to you in a way that pressures you or confuses you about your situation. One of the ways we set ourselves apart is our ability to explain these complicated products and services in a way that anyone can understand. We also have a premium maintenance club called M.A.C.H. One that gets you the fastest, most reliable service.
Recent Jobs and Reviews in Palm Harbor, FL
Our Local Reviews by City
- Bradenton, FL (9)
- Brandon, FL (1)
- Clearwater, FL (21)
- Dunedin, FL (2)
- Ellenton, FL (3)
- Greater Carrollwood, FL (1)
- Gulfport, FL (7)
- Holiday, FL (1)
- Indian Rocks Beach, FL (3)
- Indian Shores, FL (1)
- Kenneth City, FL (2)
- Lakeland, FL (1)
- Lakewood Ranch, FL (1)
- Largo, FL (22)
- Madeira Beach, FL (1)
- New Port Richey, FL (3)
- North Redington Beach, FL (5)
- Odessa, FL (4)
- Oldsmar, FL (2)
- Palm Harbor, FL (6)
- Palmetto, FL (1)
- Pinellas Park, FL (5)
- Plant City, FL (1)
- Port Richey, FL (1)
- Redington Beach, FL (1)
- Riverview, FL (3)
- Ruskin, FL (1)
- Safety Harbor, FL (1)
- Sarasota, FL (2)
- Seminole, FL (18)
- St. Petersburg, FL (43)
- Sun City Center, FL (2)
- Tampa, FL (30)
- Tarpon Springs, FL (2)
- Thonotosassa, FL (1)
- Tierra Verde, FL (1)
- Treasure Island, FL (6)
- Valrico, FL (4)
- Wesley Chapel, FL (2)
- Westchase, FL (1)
Job Locations and Reviews
Single Stage Daikin Heatpump 4.0ton 10 year parts warranty 1 year Labor warranty 1 year maintenance Required permits and inspections Warranty registration Removal and disposal of old equipment amd materials New thermostat Float switch Lineset flush Drain line flush Electric heater kit 4kw 50% Deposit due upon scheduling Remainder due upon day of job completion
Emailed estimate for daikin system
Schedule air purifier install for 12/30
Brennan G Today I visited for the compressor running louder than usual. The equipment is a 2006 5ton Trane system , uses r22. I preformed a complete inspection of the equipment and determined the change in the compressors pitch may likely just be due to age. However the equipment is also slightly low on refrigerant charge and may be causing the noise as well. I preformed a leak search and discovered the filter drier braze connection is leaking along with small leaks on the evaporator coil. There are multiple other concerns regarding the systems condition. We discussed repairs and replacement. I emailed pricing for both.88
Included: New hurricane pad and straps New Condenser whip from existing disconnect 2 - gen 3 ecobees Zone control board 3 zone dampers Zone 1 will be downstaris (1 thermostat controlling 2 dampers) Zone 2 will be upstairs ( 1 thermostat controlling 1 damper) Re strap and mastic seal all duct ( ahu1 and ahu 2) Duct cleaning and sanitation New supply and return plenum New equalizer duct Hanging kit and emergency pan Float switches Keep existing drain cleanout Lineset flush and drain flush Install original uv lamp into New air handler Electric heater kit 5kw with breaker Permits and inspections Removal and disposal of old system and materials Clean work areas Replace upstairs supply grills with high flow Cut in a new supply grill for master closet 1 year Labor warranty 10 year parts and compressor warranty
Preformed walk through with lewis
Brennan G Today I returned and located where the wall cavity air returns are. I texted the pictures to Sandy so she can share them with her contactor.
Insulated stand falling apart likely due to sucking in hot humid garage air causing excessive humidity inside stand! Blower motor making a slight grinding noise possible bearing issue! Recommend replacement of stand and plenums up to current codes and warranty replacement of blower motor.
Brennan G Today I visited for the system not cooling. I discovered the compressor fan capacitor had failed and the contactor relay was burnt. Tad elected to have the faulty components replaced and the system is now cooling. We discussed enrolling the system into our maintenance agreement. Tad declined at this time. I suggested having us return in the spring to preform a pre summer maintenance.
Brennan G Today I visited for the system not cooling. I discovered the system is low on refrigerant 410a. I preformed a leak search and found the evaporator coil is leaking. The system is out of manufacture warranty and repairs are not recommended. Andrew elected to have the system topped off for temporary cooling. I added 3 lbs to get the system cooling again. I discussed with Andrew that since the leak is not repaired the refrigerant will leak back out and refilling the system is only a temporary fix. I emailed Andrew a system replacement estimate for review.
Material list
Brennan G I edited the estimate for the system replacement to include the details that were discussed. I also created an additional estimate for blow in insulation.
We really appreciate you taking the time to share your feedback with us and the community.
Brennan G Today I visited for the system not cooling. I discovered the G wire in the thermostat was loose and the blower would not turn on. I Made the correction and the equipment is now cooling. I preformed a maintenance while onsite. The system is mostly clean. Slight dust build up on the blower wheel. May need to be pulled and cleaned next visit. I flushed the drain line and washed the condenser coil. The defrost board, condenser fan motor, and contact relay were all replaced by another company. I discovered the capacitor was slightly weak and the compressor was drawing 13RA. I was unable to tell from the account history if the maintenance agreement was still in effect or if ot is time to renew. I suggested Amanda call the office to renew the maintenance agreement.
Brennan G Provided multiple estimates for system replacements
Single Stage Heatpump System 14.3Seer2 10 year parts warranty 1 year Labor and maintenance Included: Permits and inspections Warranty registration Removal and disposal of old equipment Raised Condenser Pad New retrun box Thermostat (Digital T6) Keep existing 4" Filter Cabinet Float switches Drain flush Lineset flush Electric heater (5kw) with breaker New supply plenum, trunk lines , supply runs , seal and clean existing boots All duct sealed and strapped to code 50% deposit due upon job scheduling Remaining 50% due upon work completion
Emailed estimate
Brennan G Provided multiple estimates for system and duct replacement
Ductwork estimate
Brennan G Today I visited to provide solutions and estimates to fix air distribution and comfort problems throughout the home.
Arrived to find tripped condenser breaker Investigated entire system to find bad compressor contacted and cap. Recommended parts to be replaced to further determine what has caused the breaker to trip. Client had concerns and myself that there is more issues that can not be seen with condenser to have breaker tripped. Wanted price on new condenser also. Gave clients complete system replacement quote as well due to price difference between new condenser and whole system installation. Husband is not at home and clients want to discuss finances before pulling the trigger on any repairs. Also made wife aware of financing any job to be performed to help conserve on finds they may have put back.
Installed 9 “ 90 elbow to allow more air flow and
Found indoor unit blower running and outdoor system off along with blank t stat. Reset power to find all okay I believe the power interruption caused the issue and system has to have power turned on in the sequence of condenser first followed by the air handler
Determined the supply plenum is undersized and not allowing all air to be distributed throughout causing excessive moisture build up. Also determined the one of the supply feeds off the plenum in attic needs to be redone or rerouted due to it sweating as well.
Recharged and fixed plenum
Resealed plenum and coffin box at unit. Installed proper breaker and heat strip. System starting to dry out now. Recommend running fan in circulate mode for the day to help dry out unit! Delta T 21-22F
We’re so happy you loved your experience and can’t wait to have you back for your next service appointment.
We're so happy to hear that you had a great experience with us. Thanks for leaving a positive review.
Your kind words mean a lot to us. Thanks for the positive feedback.
We count ourselves lucky for customers like you and look forward to working with you again in the future!
We strive for FIVE (5-star reviews, that is!). Thank you for allowing us to serve you.