Check Out Our HVAC Work in Trinity FL
Mason Air Conditioning & Heating is a family-owned HVAC repair and installation company serving the residents of Trinity, FL, and the surrounding areas. We have built our business on 5-star reviews and referrals because we treat our clients the way we’d like to be treated. Whether you need your furnace, boiler, heat pump or central air conditioning attended to, we are the company for you. On top of residential HVAC, we are indoor air quality experts, too! We are also proud to be the Home of the Free Service Call meaning that you don’t owe us a dime until we start actually working on your project.
Mason will give you premium service at an exceptional value, and we’ll never talk to you in a way that pressures you or confuses you about your situation. One of the ways we set ourselves apart is our ability to explain these complicated products and services in a way that anyone can understand. We also have a premium maintenance club called M.A.C.H. One that gets you the fastest, most reliable service.
Recent Jobs and Reviews in Trinity, FL
Our Local Reviews by City
- Bradenton, FL (9)
- Brandon, FL (1)
- Clearwater, FL (21)
- Dunedin, FL (2)
- Ellenton, FL (3)
- Greater Carrollwood, FL (1)
- Gulfport, FL (7)
- Holiday, FL (1)
- Indian Rocks Beach, FL (3)
- Indian Shores, FL (1)
- Kenneth City, FL (2)
- Lakeland, FL (1)
- Lakewood Ranch, FL (1)
- Largo, FL (22)
- Madeira Beach, FL (1)
- New Port Richey, FL (3)
- North Redington Beach, FL (5)
- Odessa, FL (4)
- Oldsmar, FL (2)
- Palm Harbor, FL (6)
- Palmetto, FL (1)
- Pinellas Park, FL (5)
- Plant City, FL (1)
- Port Richey, FL (1)
- Redington Beach, FL (1)
- Riverview, FL (3)
- Ruskin, FL (1)
- Safety Harbor, FL (1)
- Sarasota, FL (2)
- Seminole, FL (18)
- St. Petersburg, FL (43)
- Sun City Center, FL (2)
- Tampa, FL (30)
- Tarpon Springs, FL (2)
- Thonotosassa, FL (1)
- Tierra Verde, FL (1)
- Treasure Island, FL (6)
- Valrico, FL (4)
- Wesley Chapel, FL (2)
- Westchase, FL (1)
Job Locations and Reviews
Arrived to replace TXV at air handler Before pumping system down I checked Freon pressures to indeed find that the valve was not metering correctly with a current evaporator temp of 33 almost 32 degrees with a lower suction pressure. This is a strong indication of why the system was not keeping temp on hotter days and reasoning on why system froze up the other day. Replaced expansion valve pulled vacuum on system. Checked operation to find much better coil temp and pressures. Was no needing of adjustment for valve which is very promising. Made Mr. Johnston aware of everything in the above text and also have a time stamped photos of when I arrived current temp in home when I started system back online and when I finished running system. The home has cooled back down to set temp while on site!
Arrived to find system frozen up and off in float switch Thawed unit and tested to find pressures at manufacture specs Tested all known functions but could not get system to show why it froze up. Will contact client in am
Upon arrival client stated system was not cooling when they had gotten home from vacation. Woke up this morning and system was running. Investigated system to find drain line plugged with debris. Checked system operation to also find weak start cap. Advised replacement of start cap to prevent potential no cool call again and clearing of drain line for free with maintenance membership. Client stated they already had a maintenance contract with another company and that when theirs is up they will call to schedule for ours. Performed drain line clearing and replacement of starting component. System now operational to manufacture specs
Blew in insulation
Arrived to find t stat set at 74 and satisfied at 74 Client had stated system would not cool this past Saturday and temp went up to 81. Removed entire charge and weighed in factory charge. Fan speed is set accordingly and adjusted mechanical txv per specs to now gather pressures and temps of 124/346 sh9 sc12 VSAT43 LSAT 106. Temp split is right at 20 degrees I have 80 degree air entering air handler and 61 degree air exiting. Home will take some time to cool down today as I have been turning system off frequently to continuously adjust txv. If problem still occurs made client aware we will return to fully insulate attic.
Completed duct work
Arrived to air handler set to 5 tons of air movement and causing system to not cool well. Wired system to 3 ton and check operation to find all okay. Client had concerns of water in can light in kitchen after our work was done. Investigated duct system to find duct system old and brittle causing ducts to sweat and fill with water. Made client aware this had been a on going issue and had nothing to do with duct cleaning.
Arrived to find bad start cap Replaced with new and also made client aware of noisy contactor soon to go also. Client decided to replace both on site. Checked total system operation to find working as designed now. Informed client that system may need surge protection and to keep an eye on unit for the future.
Upon arrival client stated system randomly stopped cooling and he had to turn breaker off and back on then system started working again. Inspected entire system to find the compressor is pulling excessive starting amps of 159! Called Rheem supplier and was informed that 9yr old system has no warranty left. Made client aware that we could preform a band aid repair today in hopes to buy some time. Client invested in band aid repair today and requested system replacement quotes. Installed start assist to have system decrease only 23.7 amps! System is still drawing 136 starting amps which is still a little excessive and made client aware if they chose to replace system within 30 days we would credit the start assist cost towards the new system.
Adjusted refrigerant charge to factory specifications
Performed system maintenance. Found equipment and all small parts operating to manufacturer specs at this time. Did have complaints of one bedroom not feeling cool enough. Damper was closed for 5" duct for room in question. Opening damper increased airflow and took care of noise complaint. If cooling problem persist suggest up sizing duct to a 7". Suggest keeping up with the regular maintenance.
Installed 3 ton unit plus cleaned 17 total vents
Maintenance
Service Call Performed system maintenance. Found bad capacitor for compressor and fan located in the condenser Equipment and all small parts operating to manufacturer specs at this time. Suggest to keep up with the regular maintenance.
Service Call
Replaced contactor and repaired short in high pressure switch, also re programmed thermostat
Unit is low on refrigerant. This option will adjust the refrigerant charge and return unit to factory operation levels.
Performed and completed maintenance on indoor and outdoor equipment
Relocated condenser
2015 Rheem variable speed HP 5 ton