Check Out Our HVAC Work in Indian Rocks Beach FL
Mason Air Conditioning & Heating is a family-owned HVAC repair and installation company serving the residents of Indian Rocks Beach, FL, and the surrounding areas. We have built our business on 5-star reviews and referrals because we treat our clients the way we’d like to be treated. Whether you need your furnace, boiler, heat pump or central air conditioning attended to, we are the company for you. On top of residential HVAC, we are indoor air quality experts, too! We are also proud to be the Home of the Free Service Call meaning that you don’t owe us a dime until we start actually working on your project.
Mason will give you premium service at an exceptional value, and we’ll never talk to you in a way that pressures you or confuses you about your situation. One of the ways we set ourselves apart is our ability to explain these complicated products and services in a way that anyone can understand. We also have a premium maintenance club called M.A.C.H. One that gets you the fastest, most reliable service.
Recent Jobs and Reviews in Indian Rocks Beach, FL
Our Local Reviews by City
- Bradenton, FL (9)
- Brandon, FL (1)
- Clearwater, FL (20)
- Dunedin, FL (2)
- Ellenton, FL (3)
- Greater Carrollwood, FL (1)
- Gulfport, FL (7)
- Holiday, FL (1)
- Indian Rocks Beach, FL (3)
- Indian Shores, FL (1)
- Kenneth City, FL (2)
- Lakeland, FL (1)
- Lakewood Ranch, FL (1)
- Largo, FL (22)
- Madeira Beach, FL (1)
- New Port Richey, FL (3)
- North Redington Beach, FL (5)
- Odessa, FL (4)
- Oldsmar, FL (2)
- Palm Harbor, FL (6)
- Palmetto, FL (1)
- Pinellas Park, FL (5)
- Plant City, FL (1)
- Port Richey, FL (1)
- Redington Beach, FL (1)
- Riverview, FL (3)
- Ruskin, FL (1)
- Safety Harbor, FL (1)
- Sarasota, FL (2)
- Seminole, FL (18)
- St. Petersburg, FL (43)
- Sun City Center, FL (2)
- Tampa, FL (30)
- Tarpon Springs, FL (2)
- Thonotosassa, FL (1)
- Tierra Verde, FL (1)
- Treasure Island, FL (6)
- Valrico, FL (4)
- Wesley Chapel, FL (2)
- Westchase, FL (1)
Job Locations and Reviews
Brennan G Today I visited for units 304 not cooling. I discovered the low voltage connections on the roof were corroded. I remade the connections and the system is now operational. Verified the system is cooling normally before departure.
Changed old condenser and air handler to new ones, changed thermostat to new
Brennan G Today I visited for the system not cooling. The condenser system on the roof will not turn on. I suspect the system is shut down on low refrigerant pressure. The system and panel is so severely rusted/ corroded I was unable to get the panel off to complete the diagnosis. Due to the condition of the equipment repairs are not recommended. I offered to return tomorrow with tools required to complete the diagnosis however Holly opted for a system replacement estimate. I sent an estimate for a new system.
Upon arrival, client stated the maintenance people had told him his condenser had fell off the stand on rooftop.investigated condenser to find all OK. There is about 5 to 6 outdoor unit that has fallen off. The stand on rooftop. Made client aware. Client also had concerns of safety switch, tripped and investigated drain line to find Water draining freeely but was in secondary switch port. I believe maintenance may have poured cleaner in line and trip switch
Thank you for your feedback. Our team is very thankful.
Brennan G Today I visited for the system not cooling. I discovered the home was cool and the float sensor was removed before arrival. I blew the drain and watched the system run for appx 20mins before leaving. I also positioned the float sensor slightly upwards to avoid the sensor filling up from non over flow water in the pan. No charge for today's visit.
Performed maint today Checked all electrical connections Cleaned evaporator coils in place Tested all starting components Replaced #3 and #1 compressor contactors on site Replaced #2 units capacitor on site due to testing weak and contactors badly pitted. Cleaned evaporator pans and drain lines flushed with water Washed condenser coils Changed filters on site Clients stated duct we had just installed the grill is sweating. Could be from door opening and closing but wasn’t really sweating while on site this morning there is clients eating in restaurant right now and if issue keeps going will have to send installers back in the morning time to seal duct. Task Includes -Replacement of compressor contactors for units #3 and 1 -Replacement of 1 start capacitor for unit #2
Removed composite boards and added unistrut. Also retied unit down.
Installer 4 14x14 new plenum
This task is additional to what was quoted previously for 2 times a year maintenance. Includes replacement of 5 filters quarterly with maintaining systems throughout the year. (3) 18x24x1 (2) 16x20x1 Could not perform maint ceiling is being redone and can not put ladder up for rooftop. Sent estimate for new duct work to be installed for kitchen area
System estimates
Replaced leaking suction line, pressure tested and adjusted charge! System now cooling with a temp split of 23F and outgoing air temp of 48.6F
Callback see notes!
Replaced 14 supply fixed 6 inch feeding men’s bathroom.
Checked system operation to find maint supply line disconnected and completely saturated with water can not be reconnected. Need to return with 16” flex and splice collar All filters changed in site today
Arrived to find system with float switch out of its port to stay running. Blew condensation line and flushed with cleaner free of charge with clients approval for maintenance membership. Check system operation to find all okay and assured proper drainage before leaving. Task includes Blowing out condensation line Flushing with cleaner at no charge Maintenance membership
Arrived to find systems with plugged filters not allowing to cool properly Middle package system is frozen due to lack of air flow made client aware to leave off for roughly another hr then turn cool mode back on and system will cool like the others. Filters needed will be (3) 18x24x1 (2) 16x20x1 Need to return to install filters there are running systems without right now
Cleaned condensate line
Found 4 ton Goodman split system with blown out terminals on compressor. System was never registered and only had. 5 year warranty. Quoted client new carrier 4 ton base and 2 stage equipment. Client has other quotes coming in and awaiting for further approval
If system changed out 50% of this amount will be credited towards system. System 13yo American standard low on refrigerant! Likely a micro coil leak! Options presented to holly who needs to forward them to owner! Recharged system to temporarily provide cooling for the guests! System should be replaced!
Leak found in old previous welds along suction line! Recommend replacing lineset from roof line to condenser and adding a filter drier! Topped off with 3.5lbs R410a and sent estimates to holly! She is reaching out to customer for approval! Will need to schedule if approved!
Blower motor failure! Replacement quote given!
Repaired faulty, wiring, rewired, air handler, and installed new thermostat. System tested and running normally now.
Wiring issue temporarily corrected to provide cooling! Louis has notes!
Replaced transformer , changed fuse and re wired unit.
Includes all new everything from the curb up! New curb, adapters, new appropriately Sized 115 V up trap kitchen, exhaust fans, new service, disconnects, and new grease trap receptacles.
We're delighted to hear that our heating and cooling service met your expectations. Thank you for your kind words.